Abstract

In this research, the results of different weight percentage of glass fiber (30, 40 & 50), cement (0, 3 & 6) and polyester resin (70, 60 & 50), on the properties of glass fiber-cement-polyester composites are investigated. The specimens are prepared by hand lay-up technique. All the specimens are tested for tensile and flexural strength as per ASTM standards. Results showed that escalation in glass fiber wt.% improved the tensile strength (by 9% at 40 wt.% and 17% at 50 wt.%) and flexural strength (by 10% at 40 wt.% and 16.5% at 50 wt.%). Whereas an increase in cement weight percentage decreases tensile strength and increases flexural strength. The failure of the sample is due to glass fiber pull out and rupture of the matrix, under tensile load.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.