Abstract
Coaxial-disk transitions can generate non-uniform magnetic fields and abrupt impedance variations in magnetically insulated transmission lines (MITLs), resulting in disturbed electron flow and non-negligible current loss. In this paper, 3D particle-in-cell simulations are conducted with UNPIC-3d to investigate the current loss mechanism and the influence of the input parameters of the coaxial-disk transition on current loss in an MITL system. The results reveal that the magnetic field non-uniformity causes major current loss in the MITL after the coaxial-disk transition, and the non-uniformity decreases with the distance away from the transition. The uniformity of the magnetic field is improved when increasing the number of feed lines of a linear transformer driver-based accelerator with coaxial-disk transitions. The number of input feed lines should be no less than four in the azimuthal distribution to obtain acceptable uniformity of the magnetic field. To make the ratio of the current loss to the total current of the accelerator less than 2% at peak anode current, the ratio of the current in each feed line to the total current should be no less than 8%.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.