This paper introduces a new type of pulse tube cryocooler, three-cold-finger pulse tube cryocooler (TCFPTC), which consists of one linear compressor and three cold fingers, i.e., CFA, CFB and CFC. Those three cold fingers are driven by the linear compressor simultaneously. This paper investigates two aspects. First, it studies the mass flow distribution among the three cold fingers by varying the input electrical power. The cooling powers of the three cold fingers at constant cooling temperatures and the cooling temperatures of the three cold fingers at constant cooling powers with various input electrical powers are investigated. Secondly, the interaction among the three cold fingers is investigated by varying the heating power of any one cold finger. Generally, if the heating power applied on one cold finger increases, with its cold head temperature rising up, the cold head temperatures of the others will decrease. But, when the cooling power of CFC has been 4W, the cold head temperature of whichever cold finger increases, the cold head temperature of CFA or CFB will seldom change if its heating power keeps constant.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.