Abstract

Heavy cast components like steam turbine or valve casings made of GX13CrMoCoVNbNB9-2-1 (CB2 steel) are used in modern fossil-fired power plants for service temperatures up to 620 °C. For production welding of these huge components, high productivity and good out-of-position weldability are needed. To combine these requirements, flux-cored arc welding is a preferred welding process. A matching flux-cored wire consumable has been developed, which offers sufficient short-term mechanical properties at ambient temperature. To prove weld metal long-term properties at service temperature, uniaxial creep rupture tests at 625 °C have been started several years ago. The microstructure of a cross-weld sample, ruptured in the heat-affected zone, was investigated by light optical microscopy and scanning electron microscopy with energy dispersive X-ray analyses. Area fraction and mean radius of precipitated Laves phase and M23C6 carbides were compared to the results of MatCalc™ simulations.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.