Abstract

By the development of laminar two-phase boundary-layer analysis on pool film boiling heat transfer, system parameters and their fundamental effect on heat transfer have been disclosed. However theoretically obtained characteristics of heat transfer do not fairly compare with the experimental data, because the relevant thermophysical properties vary significantly across the vapor film, and the nature of flow process is often turbulent and of non-boundary layer. In this investigation an analysis was made on pool film boiling heat transfer from vertical plate of uniform temperature to saturated or subcooled liquid, taking into account temperature variation of all properties, and the significance of variable properties in pool film boiling was examined. By getting solutions for water at the pressure of 1,50,100 and 200 {bar}, effect of variable properties on heat transfer and distribution of velocity and temperature were clarified. The heat-transfer results were compared with the available data of pool film boiling from horizontal cylinder.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.