Abstract
The brazing processes, using Ta and Cu interlayer respectively, were carried out to study the joining of W and steel with Ni–based amorphous foil filler. The W/Ta/steel and W/Cu/steel joints were conducted in vacuum at 1050°C for 1h. The interfacial microstructure and mechanical properties of joints were investigated by scanning electron microscopy (SEM), energy dispersive spectrometer (EDS) and tensile strength measurement. The results show that a reliable bonding between W and steel could be obtained by using both Ta and Cu interlayer. The fracture sources of W/steel brazing joints were predominantly in the tungsten substrate near the brazing seam, which agrees reasonable well with the calculation result of finite element method (FEM). The average tensile strength of W/Ta/steel and W/Cu/steel joints were 257.8MPa and 276.7MPa respectively. Comparing with hard interlayer Ta, soft interlayer Cu could reduce residual tress in W substrate and improve the mechanical property more effectively.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.