Abstract

The paper considers the system of automatic control of the tunnel kiln temperature conditions. The investigation of a delay influence on the transition process has been carried on. The transfer function of the object under control with interval coefficients taking into account possible effects of the parametric uncertainty has been obtained. A graphical method of representing the obtained results in the form of displaying the modified amplitude-phase characteristics on a complex plane has been applied which obviously demonstrates a robust absolute stability of the system under investigation. The simulation performed in the Matlab environment has proved the correctness of the results obtained.