Abstract

BackgroundTo compare the histopathological results of biceps tenodesis (BT) performed with normal, low, and high pressures for superior capsule reconstruction (SCR) in rabbits with massive rotator cuff tears.Materials and methodsThirty rabbits were divided into three groups. Rabbits 1–10 underwent SCR with BT at the same pressure (Group 1), value measured in the groove; 50% lower (Group 2); 50% higher (Group 3). After the 4-week follow-up, shoulder were en-bloc excised and histopathological evaluation was performed with modified Bonar’s scale. Results were compared between the groups, statistically.ResultsExtracellular matrix were significantly lower in group 2 compared to the other groups (p < 0.05). Cellularity levels were significantly lower in group 2 compared to the other groups (p < 0.05). Group 2 had no difference between the sides (p > 0.05). Group 2 had lower vascularity levels compared to the other groups (p = 0.01).DicsussionWhen the biceps tendon was in the bicipital groove and in a more mobile state with lower pressure exposure. BT performed with a tension that creates less pressure than the biceps in the groove is more successful in SCR.