Abstract

ObjectivesThis preliminary study aimed to clinically assess the precision of a novel optical jaw tracking system (JTS) in registering mandibular movements (MMs) of protrusion and mediotrusion. MethodsTwenty healthy participants underwent recordings using Cyclops JTS (Itaka Way Med) for functional MMs of protrusion and laterotrusion by two trained clinicians. Each subject performed five registrations at different times according to a standardized pattern within one-month period. The angulations of protrusive and mediotrusive functional paths within the first 2 mm from the maximal intercuspal position (MIP) were calculated for each trace, using a data software for angle measurements. Descriptive statistics were used to assess the repeatability of the recordings for each participant and MM. Additionally, inferential statistics were carried out on standard deviation values obtained (α=0.05). ResultsThe overall precision for all the patients was 7.07±3.37° for the protrusion angle, 5.24±2.24° for right laterotrusion and 5.14±3.06° for left laterotrusion angles. The protrusion angle ranged from 3.08° to 13.57°, while the right and left laterotrusion ranged from 1.82° to 9.42° and from 1.58° to 10.59°, respectively. No statistically significant differences were observed between different functional MM types and gender (p > 0.05). ConclusionsRecordings functional MMs of mediotrusion and protrusion using Cyclops JTS showed consistent repeatability, regardless of gender and functional MM type. The results revealed non-negligible variations that may be due to the patients’ abilities to precisely reproduce jaw movements or to the operator's ability to consistently connect the kinesiograph. Clinical significanceCapturing functional MMs digitally and importing the data into dental CAD software is essential for virtual waxing in prosthetic rehabilitations to design a functionalized adapted occlusion. Establishing the repeatability of MM recordings by a JTS is a crucial step in better understanding this novel JTS in the market. This process could facilitate the interpretation of cusp angles, aid in CAD dynamic technical modeling, and enhance clinical data communication between clinicians and technicians in a modern workflow.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call