Abstract

The post-treatment processes of plasma electrolytic oxidation (PEO) coatings for corrosion behaviors and adhesion strength are investigated by surface analysis and electrochemical measurements. When the PEO coating is treated with high-temperature oxidation (HTO), silane coupling agent (SCA) mixed with benzotriazole (BTA) exhibits the optimal corrosion behaviors and adhesion strength, the icorr decreases to 0.65 ± 0.35 μA/cm2, ip decreases to 4.37 ± 0.42 μA/cm2, the Epit increases to 369.6 ± 0.4 mVSCE and the bonding strength increases to 14.2 MPa. That was mainly attributed to the corrosive medium with a longer diffusion path to the interface. Moreover, only the HTO treatment at 150 °C showed superior properties for long-time service, the icorr was 2.00 ± 0.17 μA/cm2, ip was 12.30 ± 0.09 μA/cm2, the Epit was −4.7 ± 0.2 mVSCE and the bonding strength was 10.0 MPa. That was ascribed to both the outer hydroxide and the inner oxide depicted the higher compactness.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.