Abstract

In motors containing magnets, irreversible demagnetization failure is one of the factors that negatively affect motor performance. In this study, the traditional Axial Flux Permanent Magnet Synchronous Motor (AF-PMSM) rotor structure was changed and the structure that gained the feature of starting from the line was used. Line Start AF-PMSM with 5.5 kW shaft power has 4 poles and each pole consists of 5 magnets. Demagnetization failure was obtained by the flux values of the magnets in any pole are drawn to zero and virtual demagnetization failure is created at certain rates (20%, 40% and 60%). With FEM, the data of the healthy and faulty motor were obtained. The data are then presented comparatively. Obtained data showed that demagnetization fault in Line Start AF-PMSM negatively affects motor performance, and the results are given in detail in the article. The original aspect of the study is that the demagnetization fault in Line Start AF-PMSM was investigated for the first time with FEM.