Abstract

This paper investigated carbon steel corrosion in an enclosed environment, where one set of steel was immersed in 3.5 wt.% NaCl solution and another exposed to humid (condensation) conditions. The study employed electrochemical noise and electrochemical impedance spectroscopy techniques to monitor real time corrosion behaviour. The samples were evaluated with surface characterisation techniques including optical light microscope, scanning electron microscope with energy dispersive X-ray spectroscopy, and Raman spectroscopy. The results showed that carbon steel immersed in the liquid phase at a constant temperature exhibited the highest weight loss. However, the carbon steel exposed to water condensation (gas phase) at 80 °C manifested extensive localised corrosion. EN results agreed with the microscopy findings.