Abstract

Cross Flow Turbine usually for micro hydro-electrical power plant application especially for isolated areas. Increasing power efficiency still the most interesting topic for researches. One of the method to increase it was to control the inflow of water from the first stage to the second stage of banki blades to be a good flow trajectory and did not strike the shaft using a draft tube. This research aimed to investigate the draft tube length variations against the flow from the first stage to the second stage of Banki turbine, so that good flow trajectory, uniform color velocity contour and avoid shaft struck could be obtained. There were 2 variants runner casing and 3 variants length of draft tube, 140 mm, 240 mm, and 340 mm. The 2D and 3D geometry were drawn in CAD software, while Flow Simulation test using Solidwork Flow Simulation with a discharge of water 2 m3/min and head 5.5 m. From simulation results, shown that the second variant C2-2 was the highest efficiency and the best flow trajectory.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.