Abstract

Safety enhancement of NPP power units with water-moderated and -cooled reactors on the basis of installation of additional multifunctional low-power steam-turbine generators is studied. It is shown that the parameters of the primary and secondary loops change as the VVER-1000 reactor is cooled via the use of the residual heat in the core to generate steam that serves as the working body for a low-power steam-turbine plant. Uninterrupted power supply for the NPP’s own needs is achieved on account of the fact that in normal and emergency regimes the low-power turbine unit supplies electricity to power consumers during cooldown of a reactor in an emergency situation with a blackout. It is shown for the example of 6 and 12 MW turbine units that the residual heat from one VVER-1000 reactor is sufficient to cool two such reactors for 72 h with de-energization of the NPP and depressurization of the primary loop in one of them.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.