Abstract
This research aimed to examine the validity and reliability of GPS units located in different positions. Nine recreational soccer players (age: 23.18 ± 2.21 years; height: 176 ± 7.65 cm; and body mass: 71.13 ± 4.67 kg) participated voluntarily in the current study. Athletes were tested through the team sports simulation cycle (TSSC) protocol. This protocol consisted of a total of 1200 m. Each lap consisted of a distance of 150 m, and the athletes were asked to perform eight laps. Two GPS units (OptimEye S5; Catapult Innovations, Scoresby, Victoria) were used for each athlete during the TSSC protocol. The first unit was positioned in the scapula location, and the other GPS unit was positioned in the center of mass (COM) location, and simultaneous data were recorded. A paired-samples t-test was used to determine the difference between the meter values measured in the field and the devices. The main finding of this research was that the player load parameters, which are derived from the accelerometer in GPS units, changes with the player’s position (total player load scapula − total player Load COM p≤ 0.001, Cohen’ d−2.449). There was no statistical difference between the other parameters (total distance covered, max velocity, deceleration max and acceleration max) examined in the study. CV% and SWC values showing the reliability of total distance covered scapula (CV% = 1.41; SWC = 0.28), total distance covered COM (CV% = 3.64; SWC = 0.73), total player load scapula (CV% = 2.29; SWC = 0.46), total player load COM (CV% = 1.83; SWC = 0.37), deceleration max scapula (CV% = 3.51; SWC = 0.70), deceleration max COM (CV% = 2.78; SWC = 0.56), Acceleration max scapula (CV% = 3.85; SWC = 0.77), and acceleration max COM (CV% = 2.74; SWC = 0.55) were within acceptable limits (CV% 5). The reliability of GPS units in different locations was investigated by CV% SWC analysis. It was found that all values in the scapula and COM locations were measured validly and reliably, but the total player load measurements were statistically different in the scapula and COM.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Proceedings of the Institution of Mechanical Engineers, Part P: Journal of Sports Engineering and Technology
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.