Abstract
Technical viability and economic feasibility of improving the technology of a 450-MW CCGT unit’s participation in power load leveling of the power system operating in a GTU based CHP mode by transferring a 450-MW CCGT T-125/150 steam turbine to the driving mode instead of its shutdown are considered. It is shown that the shutdown of the steam turbine is associated with increased fuel consumption under start-up conditions, delayed steam turbine loading and the CCGT unit as a whole, and a loss of steam turbine life characteristics. The technology of transferring the 450-MW CCGT unit to the GTU based CHP mode, possible schemes of high- and low-pressure steam distributions between line water heaters, and methods and results of calculation of power parameters of the 450-MW CCGT unit with the turbine shutdown and transferring it to the driving mode in the absence and presence of peak-load heaters in the heat balance are presented. It is shown that switching the 450-MW CCGT unit from the base 290 MW electric load and 1006 GJ/h heat production to the GTU based CHP mode leads to a decrease in electric capacity of the CCGT unit by 90 MW and an increase in heat production by 335–348 GJ/h. Comparative graphs of the steam turbine start-up and the CCGT unit rated loading in the comparable variants after its operation in the GTU based CHP mode for 8–10 h are given. Evaluation techniques and results of the economic efficiency of the generator driving mode are compared with the shutdown of the steam turbine. Based on the performed calculations, it is shown that, for various combinations of fuel equivalent and electricity costs and heating tariffs, the expedient time for switching the steam turbine to the driving mode is 10–18 h. Additional advantages of the driving mode are noted, such as improvement of the steam turbine reliability due to the elimination of cyclic temperature variations of its steam-inlet elements and vibrational oscillations in the final stages of the low-pressure cylinder and the possibility of the steam turbine generator to operate as a synchronous condenser.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.