Abstract

To reduce the time of simulation for rotating Eddy current testing (RECT) technique, a simplified model without modeling probe was proposed previously. However, the applicability of the simplified simulation model was unknown. In this paper, the applicability of the simplified model for the RECT technique was investigated. The application condition of the simplified model was provided by comparing it with the results of the traditional simulation model. The simplified model was suitable for the study of cracks shorter than 70% size of the uniform Eddy current induced by the probe in a traditional model or experiment. The experiment was conducted to validate the simplified model. Moreover, using the simplified model, the effects of crack depth, orientation, and exciting frequency were studied. The deeper the crack depth was, the greater peak value of [Formula: see text] signal was. The crack angle was linear with the phase of signal. The exciting frequency affected the amplitude and phase of the signal at the same time.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.