Abstract
Particle contamination in a hard disk drive has been recognized as an important issue because particles can significantly affect the reliability of the drive. In this study, characteristics of the particle generation in a hard disk drive during the start/stop period were investigated. The number of particles generated in the drive was measured at 5 locations using CNC (condensation nucleus counter) with a sampling probe. It was found that most of the particles were generated whenever the drive started or stopped. The number of particles detected by the condensation nucleus counter depended on parameters including sampling location and sampling velocity.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.