Abstract

In this paper, the measurement of water and oxygen distributions along the modified parallel serpentine cathode flow channels has been performed using a gas chromatograph (GC). Generally, it is difficult to directly profile oxygen and water distributions where water concentration nearly reaches saturation levels. Here, the measurement of high levels of water saturation in cathode channels was carefully performed according to operating conditions such as cell voltage and air stoichiometry. GC measurement was also carried out to understand the oxygen and water distributions under channel flooding conditions. In addition, the oxygen and water vapor distributions by GC measurements for the base-line case were compared with computational fluid dynamics (CFD) simulation results. For the entrance of the flow channel, the simulated results show a good agreement with the measured results. However, some discrepancy between calculated and experimental results is found for the flow channels near the cathode outlet.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.