This paper presents the results of the study of neutron-physical characteristics of an irradiation capsule designed for radiation coloring of topazes. The studies were performed in the core of the critical facility. Sandwich screen made of boron carbide powder and tantalum foil was used to cut off thermal neutrons inside the capsule. It is shown that using sandwich screen the thermal neutron flux is reduced by 8 times, and the fast neutron flux density is practically unchanged. The activation of the tantalum monitor is reduced by more than a factor of 2. The reactivity effect from loading the irradiation capsule with the screen into the core is minus 0.9% Δk/k.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.