Abstract
We investigated both numerically and experimentally single-pass, two-pass, and four-pass Yb-doped core-pumped fiber amplifier configurations and compared their performance with respect to achievable pump-to-signal conversion efficiency. Despite numerical calculations predicting the highest efficiency in the four-pass setup, an experimentally highest conversion efficiency of 77% was achieved in the two-pass setup and only 49% in the four-pass setup. Reduced performance of the experimental four-pass fiber amplifier configuration was caused by excess coupling losses, which do not impose a fundamental limitation. At the same time, the four-pass fiber amplifier configuration demonstrated advantageous characteristics of high gain using shorter length of active fiber and lower noise figure compared with other tested configurations.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.