Abstract

This paper deals with double-pulse laser-induced breakdown spectroscopy (LIBS) underwater, which is a promising analytical method for elemental analysis in the deep sea up to a water depth of 6000 m. A double-pulse laser with a wavelength of 1064 nm is used, which provides a pulse energy of up to 266 mJ for each laser pulse (in single pulse mode), a pulse width of 5–7 ns and a pulse delay in the range of 0.5 to 20 µs. In the double-pulse LIBS method, the first laser pulse creates a cavity on the material surface, and then the second laser pulse forms the plasma in this cavity. It is expected that the plasma is affected by the cavity’s size and lifetime. For this reason, the influence of focus position, pulse energy and pulse delay on the cavity and plasma formation at shallow water depth has been investigated.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.