Abstract
The LC generator has many advantages in electrical discharge machining (EDM). It can generate high gap open voltage and high discharge current pulse with short duration under very low voltage input conditions. The shape of current pulse generated by the LC generator with higher rising speed shows superiority in machining efficiency compared to the conventional RC generator. This paper aims to investigate the influential parameters of the LC pulse generator and analyze how inductance, capacitance and switching frequency influence the discharge current pulse and gap open voltage pulse. The results of investigation are used to match the real discharge conditions by experiments. On the other hand, roughness of machined workpiece, cylindricity of drilled holes, tool wear ratio and material removal rate are investigated under different discharge parameters generated by the LC pulse generator.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.