Abstract
Indoor air quality (IAQ) in houses is often deteriorated by chemical substances emitted from heating, building materials, or other household goods. Since it is difficult for occupants to recognize air pollution, they rarely understand the actual conditions of the IAQ. An investigation into the actual condition of IAQ in houses was therefore conducted in this study. Carbon dioxide () concentrations in 24 occupied houses was measured, and the results from our analysis showed that the use of combustion heaters increased the concentration of and led to indoor air pollution. Results indicate that as outdoor temperature decreased, the frequency of ventilation decreased simultaneously, and concentration increased. Results of the questionnaire survey revealed that the actual IAQ in each house did not match the level of awareness its occupants had regarding ventilation. Along with this difficulty in perceiving air pollution, the lack of knowledge about ventilation systems and the effects of combustion heating may be additional barriers to IAQ awareness.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.