Abstract
The multistage internal airlift loop reactor (MIALR) has shown promising application prospects in gas–liquid–solid reaction systems. However, traditional MIALRs have a global circulation with strong interstage liquid-phase exchange. This paper proposes a staggered multistage internal airlift loop reactor (SMIALR) that incorporates special guide elements to create a staggered flow. Both experiments and computational fluid dynamics-population balance model simulations were conducted to investigate the hydrodynamic performances of MIALR and SMIALR. The results demonstrate that SMIALR exhibits a local circulation at each stage. Bubbles have a longer residence time in SMIALR, resulting in a 28.35%–55.54% increase in gas holdup and a 7.27%–13.69% increase in volumetric mass transfer coefficient. The gas–liquid mass transfer coefficient of SMIALR was improved by increasing the gas–liquid interfacial area. Additionally, the radial distribution of solids was found to be more uniform. This study offers insights for optimizing MIALR and provides a theoretical foundation for the design and scale-up of SMIALR.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.