Abstract

A radiotracer investigation was carried out to characterize flow dynamics of liquid phase in a pulsed sieve plate column (PSPC). Technetium-99m as sodium pertechnetate was selected and used as a radiotracer. Residence time distribution of liquid phase was measured at different operating conditions. Two different mathematical models i.e. axial dispersion and tanks-in-series with backmixing models were used to simulate the experimental data. Analysis of the experimental data revealed that flow of liquid in the PSPC can be approximated as an axially dispersed plug flow.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.