Abstract

A radiotracer investigation was previously carried out to characterize the flow of the molten glass and to identify the cause of poor quality of the glass sheets produced in an industrial solar glass production unit (SGPU-1) (Pant et al., 2016). Based on the investigations, several flow abnormalities were identified and the design of the unit was modified to improve the quality of the product and meet the product specifications. Subsequently, the radiotracer investigation was repeated in the modified unit (SGPU-1m). The results of the study showed that the dead volume and homogenization time in the modified unit were significantly reduced with improvement in mixing of the molten glass as compared to the SGPU-1. Based on the results of the two investigations, a new glass production unit (SGPU-2) with enhanced capacity was designed, fabricated and commissioned. The radiotracer investigation was repeated in the newly designed unit with an objective to evaluate and validate its design. The results indicated that the performance of SGPU-2 was as per the design criteria and the quality of the glass sheets produced was as per the desired specifications.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.