Abstract

Abstract In the present study, an existing test rig at the Institute of Thermal Turbomachinery (ITS), Karlsruhe Institute of Technology (KIT), designed for generic film cooling studies is adopted to accommodate time-resolved stereoscopic particle image velocimetry (SPIV) measurements. Through a similarity analysis, the test rig geometry is scaled by a factor of about 20. Operating conditions of hot gas and cooling air inlet and exit can be imposed that are compliant with realistic engine conditions including density ratio (DR). The cooling air is supplied by a parallel-to-hot gas coolant flow-configuration with a coolant Reynolds number of 30, 000. Time-resolved and time-averaged stereo article image velocimetry data for a film cooling flow at high DR and a range of blowing ratios are presented in this study. The investigated film cooling hole constitutes a 10 deg–10 deg–10 deg laidback fan-shaped hole with a wide spacing of P/D = 8 to insure the absence of jet interaction. The inclination angle amounts to 35 deg. The time-resolved data indicate transient behavior of the film cooling jet.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.