SUMMARY The electrostatic discharge (ESD) effect in GMR heads in the deshunting process is studied in order to prevent the damage in this process. The simulation and experiment results are investigated and compared. It is found from these results that sequences of deshunting process, currently operating, can cause the damage of GMR heads due to the ESD effect, based on the charged device model, CDM. This also shows that the voltage across GMR head, as the tweezers is used, can be raised up to ∼3.7 V which is about harmful to damage the head. Examples of damage heads confirmed by the SEM are also shown.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.