Abstract

A multi-phase AC arc has been applied to the glass melting technology. However, the electrode erosion is one of the most considerable issues to be solved. In order to investigate the erosion mechanism of the multi-phase AC arc, the combination of the high-speed video camera and the band-pass filters was introduced to measure the electrode temperature. Results indicated the tip temperature of the electrode surface in the 12-phase arc was lower than that in the 2-phase arc, while erosion rate in 12-phase arc was higher than that in the 2-phase arc. Furthermore, the dynamic behaviour of the vapours in the arc was investigated by using the same high-speed camera system. The tungsten electrode mainly evaporates at the anodic period during AC cycle. The oxygen concentration in the arc increases with larger number of the phases, resulting in the higher erosion rate in the 12-phase arc.