Abstract

The authors propose a novel approach based on partial discharge (PD) current pulse waveform analysis (PD-CPWA) in order to assess insulation degradation of solid insulators with different kinds of defects. The CPWA technique focuses on the time transition of individual PD waveform parameters like rise time, fall time and di/dt in the time-resolved waveform of a single PD current pulse. They measured PD characteristics by PD-CPWA using insulation defect model spacer. Experimental results revealed that number of positive PD increased drastically just before BD, with some discrete rest time before BD. The last PD leading to BD was successfully identified.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.