Abstract

Lignite is a low rank coal which is evenly distributed throughout the world and accounts for 45% of the total coal reserves. As it has a higher moisture content, its moisture content must be reduced in order to utilize it in power plant. In the present work, experiments on lignite has been done using a lab scale fluidized-bed reactor. Drying lignite through fluidized-bed reactor has a higher drying rate because there is good contact between particles and gas in the fluidized-bed reactor. Fluidized-bed drying can use air of 1.5 times of the minimum fluidizing velocity performance at bubbling fluidized-bed. Experiments have been performed on coal particle sizes of 0.3–1 mm, 1–1.18 mm and 1.18–2.8 mm, with operating temperatures being 100°C, 125°C and 150°C, respectively. It is found that fluidization has a higher drying rate due to the heat transfer rate through air velocity. Hence, moisture content in lignite can be dried to a desired value with a time interval of 10 min. The experiment through fluidized-bed reactor is expected to be useful for saving money and time.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.