Abstract

The potential drop (PD) method is an established non-destructive evaluation (NDE) technique. The monitoring of internal corrosion, erosion and cracks in piping systems, based on electrical field mapping or direct current potential drop array, is also known as the field signature method (FSM). The FSM has been applied in the field of submarine pipe monitoring and land-based oil and gas transmission pipes and containers. In the experimental studies, to detect and calculate the degree of pipe corrosion, the FSM analyses the relationships between the electrical resistance and pipe thickness using an electrode matrix. The relevant drag effect or trans-resistance will cause a large margin of error in the application of resistance arrays. It is the first time that the drag effect in the paper is investigated and analysed in resistance networks with the help of the FSM. Subsequently, a method to calculate the drag factors and eliminate its errors is proposed and presented. Theoretical analysis, simulation and experimental results show that the measurement accuracy can be improved by eliminating the errors caused by the drag effect.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.