Abstract

This article examined steel frames with shear beam-column connections to determine the effectiveness of different masonry infill walls under progressive collapse. This research concentrated on the shear connection, which is the most common type of steel beam-column connection in steel buildings. Furthermore, this work experimentally evaluated one-third-scale steel-framed configurations with a single shear beam-column connection and another infilled steel frame wall configuration from the literature to verify the validity of 3D finite element models developed using the program ABAQUS. Finite element models were then used to investigate 16 different kinds of steel frames with infill masonry as well as the influence of multiple frames and the number of stories. In addition, the effects of a fully infilled frame and those of a bare frame and an infilled frame with openings were compared in flexural and catenary action phases. Results revealed that the steel building’s structural strength and energy dissipation against progressive collapse are significantly improved by infill walls.

Highlights

  • Steel-framed multi-story structures are exposed to a wide variety of operational circumstances and situations during their service life

  • Several studies have investigated the progressive collapse of buildings exposed to accidental loads; the majority of studies have concentrated on bare framed structures and not filled frames, while little research has explored reinforced concrete (RC) buildings (Yu et al, 2019; Wang et al, 2020)

  • We looked into the effects of several frame types, including fully infilled, bare, and infilled with openings, as well as the impact of different numbers of frames and stories

Read more

Summary

INTRODUCTION

Steel-framed multi-story structures are exposed to a wide variety of operational circumstances and situations during their service life. Shan et al (2016) studied the effects of infill walls on the progression of collapse in two one-third-scale, four-span, two-story RC frame buildings to identify the impact of quasi-static load and column removal scenarios. They determined that infilled walls may increase the resistance to progressive collapse by functioning as compressive struts that alternately distribute removal column stresses. Infill walls have a significant impact on the maximum applied vertical load and the initial rigidity This effect reduces ductility and alters the steel frame’s failure processes. Masonry infill walls were compared in flexural and catenary action phases on the basis of their mechanisms of failure and load-displacement response

EXPERIMENTAL SPECIMENS AND TEST SETUP
EXPERIMENTAL RESULTS
FE MODELING
Material modeling
Mesh generation
Loading and boundary conditions
FE model validation
Models for the Parametric Analysis
Effects of multiple of frames and stories
Effects of infill wall
Effects of the partial infill wall arrangement
Effects of the opening in infill wall
COMPARISON OF PROTOTYPE INFILL WALL STEEL FRAMES
CONCLUSIONS