Abstract
The corrosion mechanism of the overhead pipeline of the H2S stripper tower was studied by macro examination, metallography, SEM and EDS analysis. The primary reason for the corrosion is the unsuitable material selected for the inhibitor injection pipe. In a H2S + HCl + NH3 + H2O environment, first dew point corrosion occurs. Then oil and gas erosion corrosion causes the injection tube to perforate and break, which directly alters the flow pattern and temperature in the overhead pipeline. Eventually, the tube is broken by erosion and acid corrosion. A computational fluid dynamic tool has been used for the simulation of the multiple phases inside the corroded pipe. The numerical simulation proves our conclusion of the development of corrosion in multiple locations.
Published Version
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.