Abstract

The causes of the honeycomb core node separation/core crush defects of fiberglass sandwich panel is analyzed. The porosity of skin and leakage of vacuum bag under high-pressure curing environment are identified as root causes based on the analysis of historical data and designed simulation testes, and approved by statistic analysis calculation also. The relationship of core thickness and the opportunity of the defects appearing are discovered by tests.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.