Abstract

This study presents a comparative evaluation of proportional integral (PI) controller and fuzzy logic controller (FLC) for a modified Inductance-Capacitance-Inductance resonant converter. It has been simulated and the performance is analysed. A three-element LCL resonant converter working under load-independent operation is presented in this study. In this study, the applicability of the Philips Advanced RISC Machine (ARM) processor LPC 2148 is also investigated as the controller for resonant converter. The comparison study indicates the superiority of fuzzy control over the conventional control methods and these results are presented. MATLAB was used to model the LCL topology for varied loads and LCL configurations. The LCL resonant inverter is proposed for applications in high-frequency distributed AC power systems and resonant converter is proposed for applications in many space and radar power supplies. This study presents the design, simulation and experimental results for a 133-W, 50-KHz LCL resonant converter having efficiencies >89% down to resistive loads of 50%. Efficiencies >80% were obtained at significantly reduced loads (11%).

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.