For practical applications the Euler-Euler two-fluid model relies on suitable closure relations describing interfacial exchange processes. An ongoing effort at HZDR has led to a validated set of closures for adiabatic bubbly flows that is applicable under a rather broad range of conditions including flows in pipes and bubble columns. Up to now, however, only flows with stationary mean values have been considered. The present contribution extends the model validation to dynamic flow phenomena by considering a periodically oscillating bubble plume. Consequently, the turbulence model then runs in URANS mode. Literature data for a partially aerated flat rectangular bubble column are used for comparison. In particular, results for the plume oscillation period show good agreement between simulation and experiment.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.