Abstract
The fractal dimensions of polypyrrole (PPy) film electrodeposited on the glassy carbon (GC) electrode formed in the presence of ClO4- is obtained by cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) methods in different film thicknesses and various synthesis temperatures. Atomic force microscopy (AFM) technique was employed to analyze fractal structure of film. Anomalous diffusion through the film in which mean squared displacement of particles has not a linear dependence with time (〈x2〉∝tγ) has been discussed and values of γ that is the characteristic of anomalous diffusion is obtained by EIS method and then the relation between fractal dimension and anomalous diffusion has been investigated.
Published Version
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.