Abstract
Nitrification of secondary effluent using a variant of the vertical flow bed system was investigated. In this vertical flow bed oxygen required for the nitrification process is supplied by a passive air pump. The passive air pump is based on a fill and draw cycle, where oxygen depleted air is removed from the system and fresh air is introduced. Each volume of effluent drained is displaced by an equal volume of fresh air. Experimental results of nitrification and the corresponding oxygen consumption show good agreement with theoretical calculations based on physico-chemical considerations.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.