Abstract

A study of the aerodynamics and heat transfer of a jet modular recuperator with a change in its geometric characteristics has been carried out. The influence of the in-line and staggered arrangement of the blowing holes, as well as the diameter of the perforated pipe is considered. In all considered variants, the number of holes, their diameter and gas flow rate through the recuperator remained unchanged. Numerical modeling of the problem was carried out in a three-dimensional setting using the ANSYS Fluent 15.0 software package. It was found that with the in-line arrangement of the blowing holes, secondary flows are formed between their longitudinal rows in the form of swirling jets of opposite rotation directed towards the outlet section of the recuperative device, through which the main part of the heated air flows out. With the staggered arrangement of the blowing holes, the formation of spiral vortices is disturbed, the air flow is carried out along the entire cross section of the annular channel, increasing the drift effect of the flow on the impact jets, which leads to a decrease in the intensity of heat transfer and its uniformity along the length of the working surface. An increase in the diameter of the inner perforated pipe leads to a decrease in the drift effect of the cocurrent flow on the jets, an increase in the distribution uniformity of the heat flux along the length of the heat transfer surface, and an increase in the heat transfer coefficient.