Abstract

The separating/reattaching flow over an axisymmetric backward-facing step is analyzed experimentally by means of particle image velocimetry (PIV). The main purpose of the measurements is the investigation of the mean flow field as well as of the Reynolds stress distributions at a Mach number of 0.7 and at a Reynolds number of 3.3×105 based on the step height. Due to the strong progress of optical flow measurements in the last years it was possible to resolve all flow scales down to 180μm (≈1% of the step height) with high precision. Thanks to the high spatial resolution it was found for the first time that the Reynolds stress distribution features a local minimum between the first part of the shear layer and a region inside the recirculation region. This implies a more complex wake dynamics than assumed before.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.