Abstract
Previous research has shown that the performance of a single piezoelectric (PZT) fan cooling system that is strongly affected by the operating frequency, fan amplitude, fan arrangement, and power consumption. Moreover, new dimensionless numbers, including Mp and Ri, have been defined to analyze the performance of the cooling system. In this study, an innovative multiple vibrating-fan cooling system has been developed by using PZT force and magnetic force. In this design, a PZT plate can be used to actuate five vibrating fans simultaneously. The performance of the system is demonstrated by the total amplitude of the system. The total amplitude of the single PZT fan system was 8mm while the total amplitude of the multiple vibrating-fan system was 31mm under the same power consumption. Furthermore, the multiple vibrating-fan system can be embedded into a heat sink directly. The temperature of the heat sink dropped from 67°C to 50°C when the system was operated under the condition of 36.4Hz, 50V, and λ=2mm. The result shows that the temperature drop reaches 17°C under a power consumption of 0.03W.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.