Abstract

This paper briefly describes the background to light earth buildings and details a series of moisture measurements undertaken upon the clay and straw (light earth) constructed walls of two U.K.-based buildings. The methodology of measurement that was based upon previous studies undertaken on walls made from straw bales is described. A novel “in-wall” wet heating system used in one of the two buildings allows the investigation of the effects of direct wall heating upon the distribution of moisture in the walls. The influence of exterior and interior temperature and humidity are described as are the variations in moisture migration introduced by the in-wall heating system. It was concluded that both buildings have exterior wall moisture content readings that indicate little risk of degradation due to interior wall moisture levels (although the Studio walls do exhibit higher and if suffered over long time periods, dangerous moisture readings for part of the measurement period).

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.