Abstract

BackgroundNumerous reports have shown that rigid spinal fixation contributes to a series of unwanted complications in lumbar fusion procedure. This innovative micro-dynamic pedicle screw study was designed to investigate the biomechanical performance of lumbar implants using numerical simulation technique and biomechanical experiment.MethodsInstrumented finite element models of three configurations (dynamic fixation, rigid fixation and hybrid fixation) using a functional L3-L4 lumbar unit were developed, to compare the range of motion of the lumbar spine and stress values on the endplate and implants. An in vitro experiment was simultaneously conducted using 18 intact porcine lumbar spines and segmental motion analyses were performed as well.ResultsSimulation results indicated that the dynamic fixation and the hybrid fixation models respectively increased the range of motion of the lumbar spine by 95 and 60% in flexion and by 83 and 55% in extension, compared with the rigid fixation model. The use of micro-dynamic pedicle screw led to higher stress on endplates and lower stress on pedicle screws. The outcome of the in vitro experiment demonstrated that the micro-dynamic pedicle screw could provide better range of motion at the instrumented segments than a rigid fixation.ConclusionThe micro-dynamic pedicle screw has the advantage of providing better range of motion than conventional pedicle screw in flexion-extension, without compromising stabilization, and has the potential of bringing the load transfer behavior of fusional segment closer to normal and also lowers the stress values of pedicle screws.

Highlights

  • Numerous reports have shown that rigid spinal fixation contributes to a series of unwanted complications in lumbar fusion procedure

  • The purpose of this study was to characterize the biomechanical properties of the micro-dynamic pedicle screw (MDPS) for the lumbar spine to compare its kinematic and biomechanical performance against that of traditional rigid pedicle screws (PS)

  • Each configuration instrumented model demonstrated a significant reduction in segmental range of motion (ROM) compared to the intact model

Read more

Summary

Introduction

Numerous reports have shown that rigid spinal fixation contributes to a series of unwanted complications in lumbar fusion procedure. This innovative micro-dynamic pedicle screw study was designed to investigate the biomechanical performance of lumbar implants using numerical simulation technique and biomechanical experiment. Conventional rigid pedicle screws provide over stability leading to stiffness of instrumented segments, stress concentration of implants and stress shielding of the interbody space. The mechanism of various dynamic implant designs currently available is mainly based on two components: one is the rod, the other is the pedicle screw. The most representative one is the Cosmic system, which features a hinge joint between the head and the threaded part.

Objectives
Methods
Results
Discussion
Conclusion

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.