Abstract

An effective design technique for symmetrical coupled shear walls is presented in this paper. The proposed formulation, including assumptions and steps with mathematical formulation, has been elaborated to arrive at the design technique. An example has been considered to validate the technique with the DRAIN-3DX and SAP non-linear analysis. A parametric study has also been considered to find out the limitations of this technique and suggest remedial action. It is concluded that the proposed design technique can be considered in the design of coupled shear walls under seismic motion.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.