Abstract

The young water fraction (Fyw), the proportion of water younger than 2-3 months, was investigated in soil-, ground- and stream waters in the 0.56 Km2 sub-humid Mediterranean Can Vila catchment. Rain water was sampled at 5-mm rainfall intervals. Mobile soil water and groundwater were sampled fortnightly, using suction lysimeters and two shallow wells, respectively. Stream water was dynamically sampled at variable time intervals (30 minutes to 1 week), depending on flow. A total of 1,529 18O determinations obtained during 58 months were used. The usual hypothesis of rapid evapotranspiration of summer rainfall could not be maintained, leading to discard the use of an “effective precipitation” model. Soil mobile waters had Fyw up to 34%, while in ground and stream were strongly related to water table and discharge variations, respectively. In stream waters, due to the highly skewed flow duration curve, the flow-averaged young water fraction (F*yw) was 22.6%, whereas the time-averaged Fyw was 6.2%. Nevertheless, both F*yw and its exponential discharge sensitivity (Sd) showed relevant changes when different 12-month sampling periods were investigated. The availability of Sd and a detailed flow record allowed us to simulate the young water fraction that would be obtained with a virtual thorough sampling (F**yw). This showed that underestimation of F*yw is associated with missing the sampling of highest discharges and revealed underestimations of F*yw by 25% for the dynamic sampling and 66% for the weekly sampling. These results confirm that the young water fraction and its discharge sensitivity are metrics that depend more on precipitation forcing than on physiographic characteristics, so the comparisons between catchments should be based on mean annual values and inter-annual variability. They also support the dependence of the young water fraction on the sampling rate and show the advantages of flow-weighted F*yw. Water age investigations should be accompanied by the analysis of flow duration curves. In addition, the simulation of F**yw is proposed as a method for checking the adequacy of the sampling rate used.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.