Abstract

Polymeric parts produced by Laser Sintering (LS) present a consistent amount of pores with a wide pore size distribution. The knowledge about the porosity value and its distribution within the part allows to perform a quality control of the LS process, and gives insights in how to improve it. In this work the influence of the sample size on the porosity measurement is discussed, as well as its representativeness of the LS process itself. The reliability of porosity measurement of those parts using X-ray Computed Tomography (CT) is assessed taking into account the influence of the CT scanning parameters, the reconstruction and noise reduction algorithms using a design-of-experiment approach. The quality of the CT datasets obtained is assessed by calculating Contrast-to-Noise Ratio (CNR) and Signal-to-Noise Ratio (SNR) on representative reconstructed images. Repeatability of the measurements is also assessed along the entire workflow: CT acquisition, reconstruction and porosity measurement using commercial software packages.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.