Abstract

SummaryUsing circuit theory, this letter investigates the output voltage characteristics of three‐coil inductive power transfer (IPT) system against load variations and determines the operating frequency to achieve a constant output voltage. First, a three‐coil IPT system is modeled, and the analytical expression of the root‐mean‐square of the output voltage is derived. By substituting the coupling coefficient, the quality factor, and the resonant frequency, we propose an intuitive method of calculating the frequency for load‐independent output voltage for the first time. When the coupling coefficient is relatively small, there are three frequencies that achieve load‐independent output voltage. If the coupling coefficient increases and is greater than , only two frequencies can achieve load‐independent output voltage. Experiments are conducted to confirm these conclusions. Copyright © 2015 John Wiley & Sons, Ltd.