Abstract

The effectiveness of the execution of emergency operation procedures (EOPs) for an advanced boiling water reactor (ABWR) during postulated accident conditions using MAAP 4 code is discussed in this paper. The simulation scenarios included the loss of turbine driven feedwater pump (LOTDRFP), the anticipated transients without scram (ATWS), and the loss of coolant accident (LOCA). Based on the comparisons of responses on different parameters for cases with and without EOP actions, we concluded that the EOPs could effectively mitigate the consequences of the accidents. In addition, the emergency depressurization (ED) timing and the times spent between executing the EOP steps were also considered. The simulation results clearly reveal that both the earlier execution of ED and the decrease of times spent between each EOP step could delay the boron injection and leave the operator ample time to take some other remedy actions for reactor safe shutdown.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call